libata: move PMP SCR access failure during reset to ata_eh_reset()

If PMP fan-out reset fails and SCR isn't accessible, PMP should be
reset.  This used to be tested by sata_pmp_std_hardreset() and
communicated to EH by -ERESTART.  However, this logic is generic and
doesn't really have much to do with specific hardreset implementation.

This patch moves SCR access failure detection logic to ata_eh_reset()
where it belongs.  As this makes sata_pmp_std_hardreset() identical to
sata_std_hardreset(), the function is killed and replaced with the
standard method.

Signed-off-by: Tejun Heo <htejun@gmail.com>
This commit is contained in:
Tejun Heo 2008-04-07 22:47:20 +09:00 committed by Jeff Garzik
parent ac371987a8
commit 5958e3025f
5 changed files with 7 additions and 40 deletions

View file

@ -1025,8 +1025,6 @@ static inline int ata_acpi_cbl_80wire(struct ata_port *ap,
* PMP - drivers/ata/libata-pmp.c
*/
extern int sata_pmp_qc_defer_cmd_switch(struct ata_queued_cmd *qc);
extern int sata_pmp_std_hardreset(struct ata_link *link, unsigned int *class,
unsigned long deadline);
extern void sata_pmp_error_handler(struct ata_port *ap);
/*