2019-03-02 18:45:10 +01:00
<!--
EVERSPRING AN163 PLUG-IN ON/OFF MODULE WITH METERING
https://products.z-wavealliance.org/products/979
2019-05-03 18:08:20 +08:00
--><Product Revision= "2" xmlns= "https://github.com/OpenZWave/open-zwave" >
<MetaData >
<MetaDataItem name= "OzwInfoPage" > http://www.openzwave.com/device-database/0060:0005:0004</MetaDataItem>
<MetaDataItem name= "ProductPic" > images/everspring/an163.png</MetaDataItem>
<MetaDataItem id= "0005" name= "ZWProductPage" type= "0004" > https://products.z-wavealliance.org/products/979/</MetaDataItem>
<MetaDataItem name= "Name" > On/Off Plug with metering</MetaDataItem>
<MetaDataItem id= "0005" name= "Identifier" type= "0004" > AN163-1</MetaDataItem>
<MetaDataItem id= "0005" name= "FrequencyName" type= "0004" > U.S. / Canada / Mexico</MetaDataItem>
<MetaDataItem name= "Description" > This plug-in ON/OFF Module is able to detect current wattage (5~1440W) and overload wattage (1460~1580W) of connected non-dimmable lights or appliances.</MetaDataItem>
<ChangeLog >
2019-05-03 20:52:17 +08:00
<Entry author= "Justin Hammond - Justin@dynam.ac" date= "03 May 2019" revision= "2" > Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/979/xml</Entry>
2019-05-03 18:08:20 +08:00
</ChangeLog>
</MetaData>
2019-03-02 10:26:30 -06:00
<!-- Configuration Parameters -->
<CommandClass id= "112" >
2019-05-03 18:08:20 +08:00
<Value genre= "config" index= "1" label= "True Period" max= "120" min= "0" type= "byte" units= "100ms" value= "10" >
2019-03-02 10:26:30 -06:00
<Help >
2019-03-02 18:45:10 +01:00
This is the time the switching status needs to remain unchanged after a change to cause the device to send out a status message. 0 is Disabled.
2019-03-02 10:26:30 -06:00
</Help>
</Value>
2019-05-03 18:08:20 +08:00
<Value genre= "config" index= "2" label= "Send Out Basic Command" max= "1" min= "0" size= "1" type= "list" units= "" value= "0" >
2019-03-02 10:26:30 -06:00
<Help >
2019-03-02 18:45:10 +01:00
Enable or Disable Send Basic Command to Group 2 when the local button press changes the switching state.
2019-03-02 10:26:30 -06:00
</Help>
2019-05-03 18:08:20 +08:00
<Item label= "Disable" value= "0" />
<Item label= "Enable" value= "1" />
2019-03-02 10:26:30 -06:00
</Value>
2019-05-03 18:08:20 +08:00
<Value genre= "config" index= "3" label= "Meter Report Period (W)" max= "3240" min= "0" type= "short" units= "10s" value= "3" >
2019-03-02 10:26:30 -06:00
<Help >
2019-03-02 18:45:10 +01:00
The device will report its meter value within the interval set.
Set to 0 will disable the autoreporting function.
2019-03-02 10:26:30 -06:00
</Help>
</Value>
2019-05-03 18:08:20 +08:00
<Value genre= "config" index= "4" label= "Meter Report Period (kWh)" max= "3240" min= "0" type= "short" units= "10s" value= "1440" >
2019-03-02 10:26:30 -06:00
<Help >
2019-03-02 18:45:10 +01:00
The device will report its meter value within the interval set.
Set to 0 will disable the autoreporting function.
2019-03-02 10:26:30 -06:00
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id= "133" >
<Associations num_groups= "2" >
2019-05-03 18:08:20 +08:00
<Group index= "1" label= "Lifeline" max_associations= "1" />
<Group index= "2" label= "Basic" max_associations= "4" />
2019-03-02 10:26:30 -06:00
</Associations>
</CommandClass>
</Product>