2015-06-10 21:10:36 +02:00
<?xml version="1.0" encoding="utf-8"?>
2017-07-08 22:31:42 +08:00
<Product xmlns= 'https://github.com/OpenZWave/open-zwave' Revision= "4" >
2015-06-10 21:10:36 +02:00
<!-- Configuration -->
<CommandClass id= "112" >
<Value type= "list" genre= "config" instance= "1" index= "1" label= "Enable/Disable ALL ON/OFF" value= "255" size= "1" >
2016-06-06 09:57:51 +02:00
<Help > Enable/Disable ALL ON/OFF</Help>
2015-06-10 21:10:36 +02:00
<Item label= "ALL ON disabled/ ALL OFF disabled" value= "0" />
<Item label= "ALL ON disabled/ ALL OFF active" value= "1" />
<Item label= "ALL ON active / ALL OFF disabled" value= "2" />
<Item label= "ALL ON active / ALL OFF active" value= "255" />
</Value>
<Value type= "list" genre= "config" instance= "1" index= "3" label= "Auto off relay after specified time" value= "0" size= "1" >
<Help > Auto off relay after specified time, with the possibility of manual override - immediate Off after button push.
Default value: 0 Manual override disabled</Help>
<Item label= "Manual override disabled" value= "0" />
<Item label= "Manual override enabled" value= "1" />
</Value>
<Value type= "short" genre= "config" instance= "1" index= "4" label= "Auto off" min= "0" max= "65535" value= "0" >
<Help >
2017-03-30 22:45:37 +02:00
Time period for auto off, in milliseconds (0,1 s to 6553,5 s)
2015-06-10 21:10:36 +02:00
0 - Auto off disabled
Default value: 0
</Help>
</Value>
<Value type= "list" genre= "config" instance= "1" index= "6" label= "Separation of association sending (key 1)" value= "0" size= "1" >
<Help > Activate/Deactivate association sending for group 1 - Also see param #15</Help>
<Item label= "Map status to all devices in group 1 (default)" value= "0" />
<Item label= "Map OFF status to all devices in group 1, Double click on key 1 will send ON to all devices in group 1, all dimmers set to prev.value" value= "1" />
<Item label= "Map OFF status to all devices in group 1, Double click on key 1 will send ON to all devices in group 1, all dimmers set to 100%" value= "2" />
</Value>
<Value type= "list" genre= "config" instance= "1" index= "13" label= "Inputs behaviour" value= "0" size= "1" >
<Help > In case of bi-stable switches, define their behaviour (toggle or follow)</Help>
<Item label= "Toggle" value= "0" />
<Item label= "Follow switch contact (closed=ON, open=OFF)" value= "1" />
</Value>
<Value type= "list" genre= "config" instance= "1" index= "14" label= "Inputs Button/Switch configuration" value= "1" size= "1" >
<Help > Binary inputs type configuration</Help>
<Item label= "Mono-stable input (button)" value= "0" />
<Item label= "Bi-stable input (switch)" value= "1" />
</Value>
<Value type= "list" genre= "config" instance= "1" index= "15" label= "Dimmer/Roller shutter control" value= "0" size= "1" >
2016-06-06 09:57:51 +02:00
<Help > Enable/Disable operation of dimmer or roller shutter devices associated to group 1.
2015-06-10 21:10:36 +02:00
Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation</Help>
<Item label= "Disable Dimmer/Roller shutter control" value= "0" />
<Item label= "Enable Dimmer/Roller shutter control" value= "1" />
</Value>
2016-06-06 09:57:51 +02:00
<Value type= "list" genre= "config" instance= "1" index= "16" label= "Saving state before power failure" value= "1" size= "1" >
<Help > Saving state before power failure</Help>
2015-06-10 21:10:36 +02:00
<Item label= "State NOT saved at power failure, all outputs are set to OFF upon power restore" value= "0" />
<Item label= "State saved at power failure, all outputs are set to previous state upon power restore" value= "1" />
</Value>
<Value type= "list" genre= "config" instance= "1" index= "30" label= "Relay: Response to General Alarm" value= "3" size= "1" >
<Help > </Help>
<Item label= "DEACTIVATION - no response to alarm frames" value= "0" />
<Item label= "ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value= "1" />
<Item label= "ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value= "2" />
<Item label= "ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value= "3" />
</Value>
<Value type= "list" genre= "config" instance= "1" index= "31" label= "Relay: Response to Water Flood Alarm" value= "2" size= "1" >
<Help > </Help>
<Item label= "DEACTIVATION - no response to alarm frames" value= "0" />
<Item label= "ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value= "1" />
<Item label= "ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value= "2" />
<Item label= "ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value= "3" />
</Value>
<Value type= "list" genre= "config" instance= "1" index= "32" label= "Relay: Response to Smoke, CO, CO2 Alarm" value= "3" size= "1" >
<Help > </Help>
<Item label= "DEACTIVATION - no response to alarm frames" value= "0" />
<Item label= "ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value= "1" />
<Item label= "ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value= "2" />
<Item label= "ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value= "3" />
</Value>
<Value type= "list" genre= "config" instance= "1" index= "33" label= "Relay: Response to Temperature Alarm" value= "1" size= "1" >
<Help > </Help>
<Item label= "DEACTIVATION - no response to alarm frames" value= "0" />
<Item label= "ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value= "1" />
<Item label= "ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value= "2" />
<Item label= "ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value= "3" />
</Value>
<Value type= "short" genre= "config" instance= "1" index= "39" label= "Active flashing alarm time" value= "600" min= "1" max= "20000" size= "2" >
<Help > Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id= "133" >
<Associations num_groups= "3" >
2017-06-16 09:40:27 +02:00
<Group index= "1" max_associations= "5" label= "Key no 1" auto= "false" />
<Group index= "2" max_associations= "5" label= "Key no 2" />
2016-06-06 09:57:51 +02:00
<Group index= "3" max_associations= "1" label= "Lifeline" auto= "true" />
2015-06-10 21:10:36 +02:00
</Associations>
</CommandClass>
</Product>