<Product Revision="4" xmlns="https://github.com/OpenZWave/open-zwave">
<!-- Configuration -->
<CommandClass id="112">
<Value genre="config" index="1" instance="1" label="Enable/Disable ALL ON/OFF" size="1" type="list" value="255">
<Help>Enable/Disable ALL ON/OFF</Help>
<Item label="ALL ON disabled/ ALL OFF disabled" value="0"/>
<Item label="ALL ON disabled/ ALL OFF active" value="1"/>
<Item label="ALL ON active / ALL OFF disabled" value="2"/>
<Item label="ALL ON active / ALL OFF active" value="255"/>
</Value>
<Value genre="config" index="3" instance="1" label="Auto off relay after specified time" size="1" type="list" value="0">
<Help>Auto off relay after specified time, with the possibility of manual override - immediate Off after button push.
Default value: 0 Manual override disabled</Help>
<Item label="Manual override disabled" value="0"/>
<Item label="Manual override enabled" value="1"/>
</Value>
<Value genre="config" index="4" instance="1" label="Relay 1: OFF-delay time" type="short" value="0">
<Help>Automatic turning off relay 1 after set time, (0-255) in 10ms increments for FW1.0 to FW2.0, (0-65535) in 100 ms increment for FW2.1+</Help>
</Value>
<Value genre="config" index="5" instance="1" label="Relay 2: OFF-delay time" type="short" value="0">
<Help>Automatic turning off relay 2 after set time, (0-255) in 10ms increments for FW1.0 to FW2.0, (0-65535) in 100 ms increment for FW2.1+</Help>
</Value>
<Value genre="config" index="6" instance="1" label="Managing the transmission of control commands to the devices from first group of associations (key 1)." size="1" type="list" value="0">
<Help>Correct working parameter No. 6 requires settings parameter No. 15 to 1. This activates functionality double-click - Control Dimmer/Roller Shutter. Default setting: 0</Help>
<Item label="The control commands are sent when the device is turned on and off (default)" value="0"/>
<Item label="The control commands are sent when the device is turned off. Enabling the device does not send commands controls. Double click on key 1 will send ON to all devices in group 1, all dimmers set to prev.value (ex. 50%)" value="1"/>
<Item label="The control commands are sent when the device is turned off. Enabling the device does not send commands controls. Double click on key 1 will send ON to all devices in group 1, all dimmers set to 100%" value="2"/>
</Value>
<Value genre="config" index="7" instance="1" label="Managing the transmission of control commands to the devices from second group of associations (key 2)." size="1" type="list" value="0">
<Help>Correct working parameter No. 6 requires settings parameter No. 15 to 1. This activates functionality double-click - Control Dimmer/Roller Shutter. Default setting: 0</Help>
<Item label="The control commands are sent when the device is turned on and off (default)" value="0"/>
<Item label="The control commands are sent when the device is turned off. Enabling the device does not send commands controls. Double click on key 2 will send ON to all devices in group 2, all dimmers set to prev.value (ex. 50%)" value="1"/>
<Item label="The control commands are sent when the device is turned off. Enabling the device does not send commands controls. Double click on key 2 will send ON to all devices in group 2, all dimmers set to 100%" value="2"/>
</Value>
<Value genre="config" index="13" instance="1" label="Inputs behaviour" size="1" type="list" value="0">
<Help>In case of bi-stable switches, define their behaviour (toggle or follow). Default setting: 0</Help>
<Item label="Toggle" value="0"/>
<Item label="Follow switch contact (closed=ON, open=OFF)" value="1"/>
</Value>
<Value genre="config" index="14" instance="1" label="Inputs Button/Switch configuration" size="1" type="list" value="1">
<Help>Binary inputs type configuration. Default setting: 1</Help>
<Item label="Mono-stable input (button)" value="0"/>
<Item label="Bi-stable input (switch)" value="1"/>
</Value>
<Value genre="config" index="15" instance="1" label="Dimmer/Roller shutter control" size="1" type="list" value="0">
<Help>Enable/Disable operation of dimmer or roller shutter devices associated to group 1.
Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation (only mono-stable input (button)). Default setting: 0</Help>
<Item label="Disable Dimmer/Roller shutter control" value="0"/>
<Item label="Enable Dimmer/Roller shutter control" value="1"/>
</Value>
<Value genre="config" index="16" instance="1" label="Saving state before power failure" size="1" type="list" value="1">
<Help>Saving state before power failure. Default setting: 1</Help>
<Item label="State NOT saved at power failure, all outputs are set to OFF upon power restore" value="0"/>
<Item label="State saved at power failure, all outputs are set to previous state upon power restore" value="1"/>
</Value>
<Value genre="config" index="30" instance="1" label="Relay 1: Response to General Alarm" size="1" type="list" value="3">
<Help>Default setting: 3</Help>
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
</Value>
<Value genre="config" index="31" instance="1" label="Relay 1: Response to Water Flood Alarm" size="1" type="list" value="2">
<Help>Default setting: 2</Help>
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
</Value>
<Value genre="config" index="32" instance="1" label="Relay 1: Response to Smoke, CO, CO2 Alarm" size="1" type="list" value="3">
<Help>Default setting: 3</Help>
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
</Value>
<Value genre="config" index="33" instance="1" label="Relay 1: Response to Temperature Alarm" size="1" type="list" value="1">
<Help>Default setting: 1</Help>
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
</Value>
<Value genre="config" index="39" instance="1" label="ALARM FLASHING alarm time" size="2" type="short" value="600">
<Help>Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame. Default setting: 600</Help>
</Value>
<Value genre="config" index="40" instance="1" label="Relay 2: Response to General Alarm" size="1" type="list" value="3">
<Help>Default setting: 3</Help>
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
</Value>
<Value genre="config" index="41" instance="1" label="Relay 2: Response to Water Flood Alarm" size="1" type="list" value="2">
<Help>Default setting: 2</Help>
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
</Value>
<Value genre="config" index="42" instance="1" label="Relay 2: Response to Smoke, CO, CO2 Alarm" size="1" type="list" value="3">
<Help>Default setting: 3</Help>
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
</Value>
<Value genre="config" index="43" instance="1" label="Relay 2: Response to Temperature Alarm" size="1" type="list" value="1">
<Help>Default setting: 1</Help>
<Item label="DEACTIVATION - no response to alarm frames" value="0"/>
<Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
<Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
<Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
</Value>
</CommandClass>
<CommandClass id="96">
<Compatibility>
<MapRootToEndpoint>true</MapRootToEndpoint>
</Compatibility>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="3">
<Group auto="false" index="1" label="Key no 1" max_associations="5"/>
<Group index="2" label="Key no 2" max_associations="5"/>
<Group auto="true" index="3" label="Lifeline" max_associations="1"/>
</Associations>
</CommandClass>
</Product>