2019-04-26 21:37:05 +08:00
|
|
|
<Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
|
|
|
|
<!--
|
2017-12-15 10:58:17 +01:00
|
|
|
Fibaro FGT-001
|
|
|
|
https://products.z-wavealliance.org/products/2586
|
|
|
|
config based on https://manuals.fibaro.com/content/manuals/en/FGT-001/FGT-001-EN-T-v1.0.pdf
|
|
|
|
-->
|
|
|
|
<!-- Thermostat -->
|
2019-04-26 21:37:05 +08:00
|
|
|
<CommandClass id="64">
|
|
|
|
<Value genre="user" index="0" instance="1" label="Mode" max="255" min="0" read_only="false" type="list" units="" value="0" write_only="false">
|
|
|
|
<Item label="Off" value="0"/>
|
|
|
|
<Item label="Heat" value="1"/>
|
|
|
|
<Item label="Manual Valve Control" value="31"/>
|
|
|
|
</Value>
|
|
|
|
<SupportedModes>
|
|
|
|
<Mode index="0" label="Off"/>
|
|
|
|
<Mode index="1" label="Heat"/>
|
|
|
|
<Mode index="31" label="Manual Valve Control"/>
|
|
|
|
</SupportedModes>
|
|
|
|
<Compatibility/>
|
|
|
|
</CommandClass>
|
|
|
|
<CommandClass id="67">
|
|
|
|
<Instance index="1"/>
|
|
|
|
<Value genre="user" index="1" instance="1" label="Heating" max="24" min="16" read_only="false" type="decimal" units="C" value="20" write_only="false"/>
|
|
|
|
<Compatibility>
|
|
|
|
<Base>0</Base>
|
|
|
|
<CreateVars>true</CreateVars>
|
|
|
|
</Compatibility>
|
|
|
|
</CommandClass>
|
|
|
|
<!-- Configuration -->
|
|
|
|
<CommandClass id="112">
|
|
|
|
<Value genre="config" index="1" instance="1" label="Override Schedule duration" max="10000" min="10" type="int" value="240">
|
|
|
|
<Help>This parameter determines duration of Override Schedule after turning the knob while normal schedule is active (set by Schedule CC).</Help>
|
|
|
|
</Value>
|
|
|
|
<Value genre="config" index="2" instance="1" label="Additional functions" size="4" type="int" value="1">
|
|
|
|
<Help>This parameter allows to enable different additional functions of the device.
|
2017-12-17 20:09:57 +01:00
|
|
|
1) Enable open window detector
|
|
|
|
2) Enable fast open window detector
|
|
|
|
4) Increase receiver sensitivity (shortens battery life)
|
|
|
|
8) Enable LED indications when controlling remotely
|
|
|
|
16) Protect from setting Full ON and Full OFF mode by turning the knob manually
|
|
|
|
NOTE: Parameter values may be combined, e.g. 1+8=9 means than open window detector and LED indications when controlling remotely are enabled.
|
|
|
|
</Help>
|
2019-04-26 21:37:05 +08:00
|
|
|
</Value>
|
|
|
|
<Value genre="config" index="3" instance="1" label="Additional functions status" read_only="true" size="4" type="list" value="0">
|
|
|
|
<Help>This parameter allows to check status of different additional functions.
|
2017-12-17 20:09:57 +01:00
|
|
|
1) Optional temperature sensor connected and operational
|
|
|
|
2) Open window detected
|
|
|
|
NOTE: Parameter values may be combined, e.g. 1+2=3 means than optional sensor works properly and open window detection was triggered.
|
|
|
|
</Help>
|
2019-04-26 21:37:05 +08:00
|
|
|
<Item label="None" value="0"/>
|
|
|
|
<Item label="Optional temperature sensor connected and operational" value="1"/>
|
|
|
|
<Item label="Open window detected" value="2"/>
|
|
|
|
<Item label="Optional temperature sensor and Open window detected" value="3"/>
|
|
|
|
</Value>
|
|
|
|
</CommandClass>
|
|
|
|
<!-- Map endpoints to instances -->
|
|
|
|
<CommandClass id="96">
|
|
|
|
<Compatibility>
|
|
|
|
<MapRootToEndpoint>true</MapRootToEndpoint>
|
|
|
|
</Compatibility>
|
|
|
|
</CommandClass>
|
|
|
|
<!-- Association Groups -->
|
|
|
|
<CommandClass id="133">
|
|
|
|
<Associations num_groups="1">
|
|
|
|
<Group index="1" label="Lifeline" max_associations="1"/>
|
|
|
|
</Associations>
|
|
|
|
</CommandClass>
|
2017-12-15 10:58:17 +01:00
|
|
|