Update config for ZW078 Heavy Duty Smart Switch Gen5
This commit is contained in:
parent
d20c18bde0
commit
0b08d5f67a
2 changed files with 52 additions and 38 deletions
|
@ -1,48 +1,64 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<!--
|
||||
Aeotec ZW078 Heavy Duty Smart Switch Gen5
|
||||
https://aeotec.freshdesk.com/helpdesk/attachments/6009584699
|
||||
-->
|
||||
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="1">
|
||||
--><Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
|
||||
<MetaData>
|
||||
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0086:004E:0103</MetaDataItem>
|
||||
<MetaDataItem name="ProductPic">images/aeotec/zw078.png</MetaDataItem>
|
||||
<MetaDataItem id="004E" name="ZWProductPage" type="0103">https://products.z-wavealliance.org/products/998/</MetaDataItem>
|
||||
<MetaDataItem name="ResetDescription">Press and hold the Z-Wave button for 20 seconds and then release.</MetaDataItem>
|
||||
<MetaDataItem name="WakeupDescription">N/A</MetaDataItem>
|
||||
<MetaDataItem name="ExclusionDescription">Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Z-Wave button.</MetaDataItem>
|
||||
<MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/998/Engineering Spec - Aeon Labs Heavy Duty Smart Switch Gen5.pdf</MetaDataItem>
|
||||
<MetaDataItem name="Description">Aeon Labs Heavy Duty Smart Switch is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 40A current of resister loads. It also acts as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.
|
||||
By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.</MetaDataItem>
|
||||
<MetaDataItem name="Name">Heavy Duty Smart Switch Gen5</MetaDataItem>
|
||||
<MetaDataItem id="004E" name="Identifier" type="0103">ZW078-A_Aeon_1406</MetaDataItem>
|
||||
<MetaDataItem id="004E" name="FrequencyName" type="0103">U.S. / Canada / Mexico</MetaDataItem>
|
||||
<MetaDataItem name="InclusionDescription">Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Z-Wave button.</MetaDataItem>
|
||||
<ChangeLog>
|
||||
<Entry author="Justin Hammond - Justin@dynam.ac" date="03 May 2019" revision="1">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/998/xml</Entry>
|
||||
</ChangeLog>
|
||||
</MetaData>
|
||||
<Protocol refreshonnodeinfoframe="false"/>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="list" index="3" genre="config" label="Current Overload Protection" size="1" value="0">
|
||||
<Value genre="config" index="3" label="Current Overload Protection" size="1" type="list" value="0">
|
||||
<Help>
|
||||
Current Overload Protection. Load will be closed when
|
||||
the Current more than 39.5A and the time more than 5
|
||||
seconds
|
||||
</Help>
|
||||
<Item label="Disable" value="0" />
|
||||
<Item label="Enable" value="1" />
|
||||
<Item label="Disable" value="0"/>
|
||||
<Item label="Enable" value="1"/>
|
||||
</Value>
|
||||
<Value type="list" index="20" genre="config" label="LED Mode" size="1" value="0">
|
||||
<Value genre="config" index="20" label="LED Mode" size="1" type="list" value="0">
|
||||
<Help>LED status after power on</Help>
|
||||
<Item label="Last Status" value="0"/>
|
||||
<Item label="On" value="1"/>
|
||||
<Item label="Off" value="2"/>
|
||||
</Value>
|
||||
<Value type="list" index="80" genre="config" label="Notification status" units="" size="1" value="0">
|
||||
<Value genre="config" index="80" label="Notification status" size="1" type="list" units="" value="0">
|
||||
<Help>
|
||||
Enables automatic notifications to associated devices whenever there is a state change.
|
||||
</Help>
|
||||
<Item label="None" value="0" />
|
||||
<Item label="Hail" value="1" />
|
||||
<Item label="Basic" value="2" />
|
||||
<Item label="None" value="0"/>
|
||||
<Item label="Hail" value="1"/>
|
||||
<Item label="Basic" value="2"/>
|
||||
</Value>
|
||||
<Value type="bool" index="90" genre="config" label="Enable Wattage Reports" units="" value="1">
|
||||
<Value genre="config" index="90" label="Enable Wattage Reports" type="bool" units="" value="1">
|
||||
<Help>Enable/disable Wattage threshold and percent.</Help>
|
||||
</Value>
|
||||
<Value type="short" index="91" genre="config" label="Wattage threshold" units="watts" min="0" max="32000" value="50">
|
||||
<Value genre="config" index="91" label="Wattage threshold" max="32000" min="0" type="short" units="watts" value="50">
|
||||
<Help>The minimum change in wattage for a report to be sent.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="92" genre="config" label="Wattage threshold percent" units="%" min="0" max="99" value="10">
|
||||
<Value genre="config" index="92" label="Wattage threshold percent" max="99" min="0" type="byte" units="%" value="10">
|
||||
<Help>Minimum change in percent of wattage to send a report.</Help>
|
||||
</Value>
|
||||
<Value type="button" index="100" genre="config" label="Default Group Reports" units="" write_only="true" value="0" affects="101,102,103">
|
||||
<Value affects="101,102,103" genre="config" index="100" label="Default Group Reports" type="button" units="" value="0" write_only="true">
|
||||
<Help>Set report types for groups 1, 2 and 3 to default.</Help>
|
||||
</Value>
|
||||
<Value type="int" index="101" genre="config" label="Report type sent in Reporting Group 1" units="" value="4">
|
||||
<Value genre="config" index="101" label="Report type sent in Reporting Group 1" type="int" units="" value="4">
|
||||
<Help>
|
||||
Defines the type of report sent for reporting group 1.
|
||||
1 is meter report for voltage.
|
||||
|
@ -59,7 +75,7 @@ https://aeotec.freshdesk.com/helpdesk/attachments/6009584699
|
|||
bit 0 voltage
|
||||
</Help>
|
||||
</Value>
|
||||
<Value type="int" index="102" genre="config" label="Report type sent in Reporting Group 2" units="" value="8">
|
||||
<Value genre="config" index="102" label="Report type sent in Reporting Group 2" type="int" units="" value="8">
|
||||
<Help>
|
||||
Defines the type of report sent for reporting group 2.
|
||||
1 is meter report for voltage.
|
||||
|
@ -76,7 +92,7 @@ https://aeotec.freshdesk.com/helpdesk/attachments/6009584699
|
|||
bit 0 voltage
|
||||
</Help>
|
||||
</Value>
|
||||
<Value type="int" index="103" genre="config" label="Report type sent in Reporting Group 3" units="" value="0">
|
||||
<Value genre="config" index="103" label="Report type sent in Reporting Group 3" type="int" units="" value="0">
|
||||
<Help>
|
||||
Defines the type of report sent for reporting group 3.
|
||||
1 is meter report for voltage.
|
||||
|
@ -93,41 +109,39 @@ https://aeotec.freshdesk.com/helpdesk/attachments/6009584699
|
|||
bit 0 voltage
|
||||
</Help>
|
||||
</Value>
|
||||
<Value type="button" index="110" genre="config" label="Default Group Time" units="" write_only="true" value="0" affects="111,112,113">
|
||||
<Value affects="111,112,113" genre="config" index="110" label="Default Group Time" type="button" units="" value="0" write_only="true">
|
||||
<Help>Set time interval for sending reports for groups 1, 2 and 3 to default.</Help>
|
||||
</Value>
|
||||
<Value type="int" index="111" genre="config" label="Send interval G1" units="seconds" min="0" max="65535" value="5">
|
||||
<Value genre="config" index="111" label="Send interval G1" max="65535" min="0" type="int" units="seconds" value="5">
|
||||
<Help>Defines the time interval when the defined report for group 1 is sent.</Help>
|
||||
</Value>
|
||||
<Value type="int" index="112" genre="config" label="Send interval G2" units="seconds" min="0" max="65535" value="120">
|
||||
<Value genre="config" index="112" label="Send interval G2" max="65535" min="0" type="int" units="seconds" value="120">
|
||||
<Help>Defines the time interval when the defined report for group 2 is sent.</Help>
|
||||
</Value>
|
||||
<Value type="int" index="113" genre="config" label="Send interval G3" units="seconds" min="0" max="65535" value="120">
|
||||
<Value genre="config" index="113" label="Send interval G3" max="65535" min="0" type="int" units="seconds" value="120">
|
||||
<Help>Defines the time interval when the defined report for group 3 is sent.</Help>
|
||||
</Value>
|
||||
<Value type="list" index="200" genre="config" label="Partner ID" units="" min="0" max="1" size="1" value="0">
|
||||
<Item label="Aeon Labs Standard Product" value="0" />
|
||||
<Item label="Other" value="1" />
|
||||
</Value>
|
||||
<Value type="list" genre="config" index="252" label="Lock/Unlock Configuration" min="0" max="1" size="1" value="0">
|
||||
<Value genre="config" index="200" label="Partner ID" max="1" min="0" size="1" type="list" units="" value="0">
|
||||
<Item label="Aeon Labs Standard Product" value="0"/>
|
||||
<Item label="Other" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="252" label="Lock/Unlock Configuration" max="1" min="0" size="1" type="list" value="0">
|
||||
<Help>Lock/ unlock all configuration parameters</Help>
|
||||
<Item label="Unlock" value="0"/>
|
||||
<Item label="Lock" value="1"/>
|
||||
</Value>
|
||||
<Value type="list" index="255" genre="config" label="Reset To Factory Defaults" size="4" value="1" write_only="true">
|
||||
<Help>Reset to factory defaults</Help>
|
||||
<Item label="Reset to factory default setting" value="0"/>
|
||||
<Item label="Normal" value="1"/>
|
||||
<Item label="Reset to factory default setting and removed from the z-wave network" value="1431655765"/>
|
||||
</Value>
|
||||
<Value genre="config" index="255" label="Reset To Factory Defaults" size="4" type="list" value="1" write_only="true">
|
||||
<Help>Reset to factory defaults</Help>
|
||||
<Item label="Reset to factory default setting" value="0"/>
|
||||
<Item label="Normal" value="1"/>
|
||||
<Item label="Reset to factory default setting and removed from the z-wave network" value="1431655765"/>
|
||||
</Value>
|
||||
</CommandClass>
|
||||
|
||||
<!-- Association Groups -->
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="2">
|
||||
<Group index="1" max_associations="5" label="LifeLine" />
|
||||
<Group index="2" max_associations="5" label="Retransmit Switch CC" />
|
||||
<Group index="1" label="LifeLine" max_associations="5"/>
|
||||
<Group index="2" label="Retransmit Switch CC" max_associations="5"/>
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
||||
|
||||
|
|
BIN
config/images/aeotec/zw078.png
Normal file
BIN
config/images/aeotec/zw078.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 18 KiB |
Loading…
Add table
Reference in a new issue