mirror of
https://github.com/Fishwaldo/open-zwave.git
synced 2025-03-15 19:41:36 +00:00
Update config for ZDM230 Wall Dimmer Module
This commit is contained in:
parent
426dd52e6d
commit
122df017d8
2 changed files with 110 additions and 91 deletions
|
@ -1,93 +1,112 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="2">
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" size="1" value="1">
|
||||
<Help>Dimmers controlled by this switch will start dimming from their current level.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="2" genre="config" label="Suspend Group 4" size="1" value="0">
|
||||
<Help>Disable transmitting commands to Z-Wave devices that are in Group 4 without disassociating those devices from the group.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="3" genre="config" label="Night Light" size="1" value="0">
|
||||
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="4" genre="config" label="Invert Switch" size="1" value="0">
|
||||
<Help>Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="5" genre="config" label="Ignore Start-Level (Receiving)" size="1" value="1">
|
||||
<Help>This dimmer will start dimming from its current level.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="6" genre="config" label="Don't Send Level After Dim" size="1" value="1">
|
||||
<Help>When you press and hold the bottom of the ZDM230 switch once, the Z-Wave devices that are associated into Group 1 are sent the Dim command. If this parameter is set to "Yes" the devices in Group 1 will not go to the same level as the ZDM230.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="byte" index="7" genre="config" label="On/Off Command Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="8" genre="config" label="On/Off Command Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="9" genre="config" label="Local Control Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="10" genre="config" label="Local Control Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="11" genre="config" label="ALL ON/ALL OFF Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="12" genre="config" label="ALL ON/ALL OFF Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="list" index="13" genre="config" label="Disable Group 4 During Dim" size="1">
|
||||
<Help>Units in Group 4 only track when the dimmer is being turned ON and OFF and not while dimming.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" size="1" value="0">
|
||||
<Help>The ZDM230 can operate shade control devices via its group 2.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" size="1" value="0">
|
||||
<Help>The ZDM230 can operate shade control devices via its group 3.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="19" genre="config" label="LED Transmission Indication" size="1" value="2">
|
||||
<Help>The ZDM230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
|
||||
<Item label="None" value="0" />
|
||||
<Item label="While Transmitting" value="1" />
|
||||
<Item label="One Second Maximum" value="2" />
|
||||
</Value>
|
||||
<Value type="byte" index="20" genre="config" label="Poll Group 2 Interval" units="minutes" min="1" max="255" value="2">
|
||||
<Help>Poll Group 2 Interval</Help>
|
||||
</Value>
|
||||
<Value type="list" index="22" genre="config" label="Enable Group 2 Polling" size="1">
|
||||
<Help>Poll Group 2</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
</CommandClass>
|
||||
<Product Revision="3" xmlns="https://github.com/OpenZWave/open-zwave">
|
||||
<MetaData>
|
||||
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0001:3330:444D</MetaDataItem>
|
||||
<MetaDataItem name="ProductPic">images/act/zdm230.png</MetaDataItem>
|
||||
<MetaDataItem id="3330" name="ZWProductPage" type="444D">https://products.z-wavealliance.org/products/478/</MetaDataItem>
|
||||
<MetaDataItem name="Name">ZDM230 - Dual button Wall Dimmer</MetaDataItem>
|
||||
<MetaDataItem id="3330" name="FrequencyName" type="444D">CEPT (Europe)</MetaDataItem>
|
||||
<MetaDataItem name="Description">The ZDM230 is a dual switch design, where the first switch controls the connected load and also serve as a transmitter using multiple switch taps (one group of 5 Z-Wave modules), and the second switch used as a transmitter only (controls two groups of 5 Z-Wave modules).
|
||||
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="4">
|
||||
<Group index="1" max_associations="5" label="Left Switch" />
|
||||
<Group index="2" max_associations="5" label="Right Switch" />
|
||||
<Group index="3" max_associations="5" label="Right Switch (2 Taps)" />
|
||||
<Group index="4" max_associations="5" label="Update Controller" auto="true" />
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
ZDM230 replaces an existing wall switch, and can add 3-way capability.
|
||||
|
||||
ZDM230 can be programmed as a routing slave to establish firm signal routes and can be "associated" with other Z-wave devices in order to control them.
|
||||
|
||||
ZDM230 has automatic Static Update Controller (SUC) capability. A Static Controller is one that is not moved after its addition to the network. The Static Controller can act as a gateway in the system, since other nodes always know its position. The “always listening” advantage of the Static Controller is that other nodes can transmit information frames to it whenever needed.
|
||||
|
||||
ZDM230 can be configured to Control Shades or Window Coverings via Z-Wave network</MetaDataItem>
|
||||
<MetaDataItem id="3330" name="Identifier" type="444D">ZDM230</MetaDataItem>
|
||||
<MetaDataItem name="ProductPage">http://www.smarthome-products.com/p-638-homepro-zdm230-z-wave-500-watt-dimmer-3-way-3-wire-euro.aspx</MetaDataItem>
|
||||
<ChangeLog>
|
||||
<Entry author="Justin Hammond - Justin@dynam.ac" date="03 May 2019" revision="3">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/478/xml</Entry>
|
||||
</ChangeLog>
|
||||
</MetaData>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value genre="config" index="1" label="Ignore Start-Level (Transmitting)" size="1" type="list" value="1">
|
||||
<Help>Dimmers controlled by this switch will start dimming from their current level.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="2" label="Suspend Group 4" size="1" type="list" value="0">
|
||||
<Help>Disable transmitting commands to Z-Wave devices that are in Group 4 without disassociating those devices from the group.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="3" label="Night Light" size="1" type="list" value="0">
|
||||
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="4" label="Invert Switch" size="1" type="list" value="0">
|
||||
<Help>Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="5" label="Ignore Start-Level (Receiving)" size="1" type="list" value="1">
|
||||
<Help>This dimmer will start dimming from its current level.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="6" label="Don't Send Level After Dim" size="1" type="list" value="1">
|
||||
<Help>When you press and hold the bottom of the ZDM230 switch once, the Z-Wave devices that are associated into Group 1 are sent the Dim command. If this parameter is set to "Yes" the devices in Group 1 will not go to the same level as the ZDM230.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="7" label="On/Off Command Dim Step" max="99" min="1" type="byte" units="" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value genre="config" index="8" label="On/Off Command Dim Rate" max="255" min="1" type="byte" units="x 10 milliseconds" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value genre="config" index="9" label="Local Control Dim Step" max="99" min="1" type="byte" units="" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value genre="config" index="10" label="Local Control Dim Rate" max="255" min="1" type="byte" units="x 10 milliseconds" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value genre="config" index="11" label="ALL ON/ALL OFF Dim Step" max="99" min="1" type="byte" units="" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value genre="config" index="12" label="ALL ON/ALL OFF Dim Rate" max="255" min="1" type="byte" units="x 10 milliseconds" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value genre="config" index="13" label="Disable Group 4 During Dim" size="1" type="list">
|
||||
<Help>Units in Group 4 only track when the dimmer is being turned ON and OFF and not while dimming.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="14" label="Enable Shade Control Group 2" size="1" type="list" value="0">
|
||||
<Help>The ZDM230 can operate shade control devices via its group 2.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="15" label="Enable Shade Control Group 3" size="1" type="list" value="0">
|
||||
<Help>The ZDM230 can operate shade control devices via its group 3.</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="19" label="LED Transmission Indication" size="1" type="list" value="2">
|
||||
<Help>The ZDM230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
|
||||
<Item label="None" value="0"/>
|
||||
<Item label="While Transmitting" value="1"/>
|
||||
<Item label="One Second Maximum" value="2"/>
|
||||
</Value>
|
||||
<Value genre="config" index="20" label="Poll Group 2 Interval" max="255" min="1" type="byte" units="minutes" value="2">
|
||||
<Help>Poll Group 2 Interval</Help>
|
||||
</Value>
|
||||
<Value genre="config" index="22" label="Enable Group 2 Polling" size="1" type="list">
|
||||
<Help>Poll Group 2</Help>
|
||||
<Item label="No" value="0"/>
|
||||
<Item label="Yes" value="1"/>
|
||||
</Value>
|
||||
</CommandClass>
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="4">
|
||||
<Group index="1" label="Left Switch" max_associations="5"/>
|
||||
<Group index="2" label="Right Switch" max_associations="5"/>
|
||||
<Group index="3" label="Right Switch (2 Taps)" max_associations="5"/>
|
||||
<Group auto="true" index="4" label="Update Controller" max_associations="5"/>
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
||||
|
|
BIN
config/images/act/zdm230.png
Normal file
BIN
config/images/act/zdm230.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 23 KiB |
Loading…
Add table