mirror of
https://github.com/Fishwaldo/open-zwave.git
synced 2025-03-17 12:31:37 +00:00
Add device: HomeSeer HS-LS100+ Leak Sensor
This commit is contained in:
parent
9cbe313fdc
commit
143557c91b
2 changed files with 78 additions and 0 deletions
77
config/homeseer/hs-ls100plus.xml
Normal file
77
config/homeseer/hs-ls100plus.xml
Normal file
|
@ -0,0 +1,77 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
||||
<!--
|
||||
HomeSeer HS-LS100+ Leak Sensor
|
||||
https://products.z-wavealliance.org/products/2735
|
||||
Manual: https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/2735/User%20Manual%20revised%201211.pdf
|
||||
Config capabilities: https://products.z-wavealliance.org/products/2735/configs
|
||||
-->
|
||||
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="list" index="14" genre="config" label="Basic set command" min="0" max="1" size="1" value="0">
|
||||
<Help>Enable / disable the basic set command send to group 2</Help>
|
||||
<Item label="Disable" value="0"/>
|
||||
<Item label="Enable" value="1"/>
|
||||
</Value>
|
||||
<Value type="list" index="15" genre="config" label="Value for basic set command" min="0" max="1" size="1" value="0">
|
||||
<Help>
|
||||
Define BASIC SET VALUE to nodes associated with group 2 when flooding alarm is triggered and is canceled.
|
||||
</Help>
|
||||
<Item label="255 alarm is triggered, 0 alarm is canceled" value="0"/>
|
||||
<Item label="0 alarm is triggered, 255 alarm is canceled" value="1"/>
|
||||
</Value>
|
||||
<Value type="byte" index="17" genre="config" label="Leak report interval" units="minutes" min="0" max="255" size="1" value="5">
|
||||
<Help>Leak report interval, minutes. O to disable.</Help>
|
||||
</Value>
|
||||
<Value type="list" index="18" genre="config" label="Shock sensor" min="0" max="1" size="1" value="0">
|
||||
<Help>
|
||||
When the value is Disable, the product will not sends a vibration alarm after moving or shaking.
|
||||
When the value is Enable, the product will sends a vibration alarm after moving or shaking.
|
||||
</Help>
|
||||
<Item label="Disable" value="0"/>
|
||||
<Item label="Enable" value="1"/>
|
||||
</Value>
|
||||
<Value type="byte" index="19" genre="config" label="Temperature report interval" units="minutes" min="0" max="255" size="1" value="0">
|
||||
<Help>Temperature report interval, minutes. O to disable.</Help>
|
||||
</Value>
|
||||
<Value type="short" index="20" genre="config" label="High temperature trigger value" units="" min="-670" max="2570" size="2" value="1040">
|
||||
<Help>
|
||||
Set the high temperature alarm trigger value.
|
||||
Available: -670 to 2570 (-67.0 to 257.0 °F)
|
||||
Default: 1040 (104.0 °F)
|
||||
</Help>
|
||||
</Value>
|
||||
<Value type="short" index="22" genre="config" label="Low temperature trigger value" units="" min="-670" max="2570" size="2" value="320">
|
||||
<Help>
|
||||
Set the low temperature alarm trigger value.
|
||||
Available: -670 to 2570 (-67.0 to 257.0 °F)
|
||||
Default: 320 (32.0 °F)
|
||||
</Help>
|
||||
</Value>
|
||||
<Value type="list" index="24" genre="config" label="Blinking LED when alarm triggers" min="0" max="1" size="1" value="1">
|
||||
<Help>
|
||||
When the value is Disable, the product will not alarm when being triggered.
|
||||
When the value is Enable, the product will alarm when being triggered.
|
||||
</Help>
|
||||
<Item label="Disable" value="0"/>
|
||||
<Item label="Enable" value="1"/>
|
||||
</Value>
|
||||
<Value type="list" index="32" genre="config" label="Low battery threshold" units="%" min="10" max="50" size="1" value="20">
|
||||
<Help>Low battery reporting threshold, %.</Help>
|
||||
<Item label="10" value="10"/>
|
||||
<Item label="20" value="20"/>
|
||||
<Item label="30" value="30"/>
|
||||
<Item label="40" value="40"/>
|
||||
<Item label="50" value="50"/>
|
||||
</Value>
|
||||
</CommandClass>
|
||||
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="1">
|
||||
<Group index="1" max_associations="5" label="Lifeline"/>
|
||||
<Group index="2" max_associations="5" label="Basic Set"/>
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
|
@ -696,6 +696,7 @@
|
|||
<Product type="4447" id="3035" name="HS-WS200+ Wall Switch" config="homeseer/hs-ws200plus.xml"/>
|
||||
<Product type="4447" id="3036" name="HS-WD200+ Wall Dimmer" config="homeseer/hs-wd200plus.xml"/>
|
||||
<Product type="201" id="9" name="HS-MS100+ Motion Sensor" config="homeseer/hs-ms100plus.xml"/>
|
||||
<Product type="201" id="a" name="HS-LS100+ Leak Sensor" config="homeseer/hs-ls100plus.xml"/>
|
||||
</Manufacturer>
|
||||
<Manufacturer id="0030" name="HomeSeer Tech">
|
||||
</Manufacturer>
|
||||
|
|
Loading…
Add table
Reference in a new issue