Update config for Siren MT02758

This commit is contained in:
Justin Hammond 2019-06-02 12:29:58 +08:00
parent 11cfd7e40b
commit 5f5de21c4c
2 changed files with 25 additions and 2 deletions

View file

@ -1,8 +1,31 @@
<!--
devolo Siren MT02758
http://products.z-wavealliance.org/products/2308
-->
<Product Revision="3" xmlns="https://github.com/OpenZWave/open-zwave">
--><Product Revision="4" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0175:000A:0004</MetaDataItem>
<MetaDataItem name="ProductPic">images/devolo/mt02758.png</MetaDataItem>
<MetaDataItem id="000A" name="ZWProductPage" type="0004">https://products.z-wavealliance.org/products/2308/</MetaDataItem>
<MetaDataItem name="ExclusionDescription">1. Have Z-Wave™ Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
Node ID has been excluded.</MetaDataItem>
<MetaDataItem name="Description">Siren MT02758 is a wireless siren, based on Z-Wave™ technology. It is the Z-Wave™ plus product, it support the security, OTA... Those newest features of the Z-Wave™ technology.</MetaDataItem>
<MetaDataItem name="Name">Siren</MetaDataItem>
<MetaDataItem id="000A" name="FrequencyName" type="0004">CEPT (Europe)</MetaDataItem>
<MetaDataItem id="000A" name="Identifier" type="0004">MT02758</MetaDataItem>
<MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&amp;filename=Manuals/2308/MT02758_manual.pdf</MetaDataItem>
<MetaDataItem name="ResetDescription">Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default.</MetaDataItem>
<MetaDataItem name="InclusionDescription">1. Have Z-Wave™ Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the inclusion mode.
3. After add successful, the LED will light ON 1 second</MetaDataItem>
<ChangeLog>
<Entry author="Justin Hammond - Justin@dynam.ac" date="02 Jun 2019" revision="4">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2308/xml</Entry>
</ChangeLog>
</MetaData>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value genre="config" index="7" label="Customer Function" size="1" type="list" value="0">

Binary file not shown.

After

Width:  |  Height:  |  Size: 32 KiB