@ -1,8 +1,37 @@
<!--
Simon S100 Socket iO
https://products.z-wavealliance.org/products/1869
-->
<Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
--><Product Revision="3" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0267:0000:0001</MetaDataItem>
<MetaDataItem name="ProductPic">images/simon/10002034-13X.png</MetaDataItem>
<MetaDataItem id="0000" name="ZWProductPage" type="0001">https://products.z-wavealliance.org/products/3279/</MetaDataItem>
<MetaDataItem id="0000" name="Identifier" type="0001">10003034-13X</MetaDataItem>
<MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&amp;filename=Manuals/3279/991406.pdf</MetaDataItem>
<MetaDataItem name="Name">S100 Switch IO (China)</MetaDataItem>
<MetaDataItem name="Description">Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes.</MetaDataItem>
<MetaDataItem name="ExclusionDescription">When the pushbutton is released after a press of (2sec&lt;T&lt;20sec) the device will send a NIF to exclude from Z-Wave network or perform an association with other Z-Wave device.
Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
This process does not perform a default reset of configurations.
Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton. </MetaDataItem>
<MetaDataItem id="0000" name="FrequencyName" type="0001">China</MetaDataItem>
<MetaDataItem name="ResetDescription">When the pushbutton is released after a press of (20sec&lt;T) the device will perform a factory default values operation, excluding it from network and resetíng the configuration parameters.
Main LED will perform 1 Blink with 5 sec.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.</MetaDataItem>
<MetaDataItem name="InclusionDescription">When the pushbutton is released after a press of (2sec&lt;T&lt;20sec) the device will send a NIF to include from Z-Wave network or perform an association with other Z-Wave device.
Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
This process does not perform a default reset of configurations.
Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton. </MetaDataItem>
<ChangeLog>
<Entry author="Justin Hammond - Justin@dynam.ac" date="03 Jun 2019" revision="3">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3279/xml</Entry>
</ChangeLog>
</MetaData>
<!-- COMMAND_CLASS_SWITCH_MULTILEVEL. This class is in the list reported by the device, but it does not respond to requests -->
<CommandClass id="38">
<Compatibility>