mirror of
https://github.com/Fishwaldo/open-zwave.git
synced 2025-03-15 11:31:40 +00:00
device HS-DS100+ Door/Window Sensor (#1890)
* device HS-DS100+ Door/Window Sensor * Bump revision
This commit is contained in:
parent
77492d7137
commit
bf59235017
5 changed files with 66 additions and 1 deletions
58
config/homeseer/hs-ds100plus.xml
Normal file
58
config/homeseer/hs-ds100plus.xml
Normal file
|
@ -0,0 +1,58 @@
|
|||
<Product Revision="1" xmlns="https://github.com/OpenZWave/open-zwave">
|
||||
<MetaData>
|
||||
<MetaDataItem name="Name">Door/Window Sensor</MetaDataItem>
|
||||
<MetaDataItem name="Description">Door/Window Sensor is a wireless reed sensor powered by AAA battery. It is used for detecting the opening or closing of doors, windows. It can communicate with an associated Z-Wave device, such as Siren, Smart Switch, etc.</MetaDataItem>
|
||||
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/000C:0008:0201</MetaDataItem>
|
||||
<MetaDataItem name="ProductPage">https://homeseer.com/sensors/</MetaDataItem>
|
||||
<MetaDataItem name="ProductSupport">https://homeseer.com/support-home/</MetaDataItem>
|
||||
<MetaDataItem name="ProductPic">images/homeseer/hs-ds100plus.png</MetaDataItem>
|
||||
<MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2958/DoorWindowSensorEngineeringSpecification.pdf</MetaDataItem>
|
||||
<MetaDataItem name="WakeupDescription"></MetaDataItem>
|
||||
<MetaDataItem name="InclusionDescription">1. Insert the AAA battery.
|
||||
2. Set the Z-Wave network main controller into learning mode.
|
||||
3. Triple or single short press the Z-button.
|
||||
4. If the add for inclusion is successful, the LED will blink less than 5 seconds and then keep on 3 seconds. Otherwise, the LED will blink 5 seconds and then turn off, in which case you need to repeat the process from step 2.
|
||||
</MetaDataItem>
|
||||
<MetaDataItem name="ResetDescription">1. Insert the AAA battery.
|
||||
2. Pressing and holding the Z button for more than 20 seconds,
|
||||
3. Led will keep on until the Z-Button is released, and it will reset to factory default when the button is released.
|
||||
|
||||
Using this procedure only in the event that the network primary controller is missing or otherwise inoperable.
|
||||
</MetaDataItem>
|
||||
<MetaDataItem name="ExclusionDescription">1. Insert the AAA battery.
|
||||
2. Set the Z-Wave network main controller into learning mode.
|
||||
3. Triple clicking the Z-button.
|
||||
4. If the remove for exclusion, the LED will turn off within 1 second. Otherwise, the LED will blink 5 seconds and then turn off, in which case you need to repeat the process from step 2.
|
||||
</MetaDataItem>
|
||||
<MetaDataItem id="0008" name="ZWProductPage" type="0201">https://products.z-wavealliance.org/products/2958/</MetaDataItem>
|
||||
<MetaDataItem id="0008" name="FrequencyName" type="0201">U.S. / Canada / Mexico</MetaDataItem>
|
||||
<MetaDataItem id="0008" name="Identifier" type="0201">HS-DS100+</MetaDataItem>
|
||||
<ChangeLog>
|
||||
<Entry author="Jim Stuhlmacher - jim@stuhlmacher.us" date="17 Jul 2019" revision="1">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/Products/2958/XML</Entry>
|
||||
</ChangeLog>
|
||||
</MetaData>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value genre="config" index="15" label="Value for basic set command" max="1" min="0" size="1" type="list" value="0">
|
||||
<Help>Door/Window Sensor can reverse its value of BASIC SET when the magnet is triggered.
|
||||
</Help>
|
||||
<Item label="Send BASIC SET VALUE = 255 to nodes associated with group 2 when door/window is opened. Send BASIC SET VALUE = 0 to nodes associated with group 2 when door/window is closed." value="0"/>
|
||||
<Item label="Send BASIC SET VALUE = 0 to nodes associated with group 2 when door/window is opened. Send BASIC SET VALUE = 255 to nodes associated with group 2 when door/window is closed." value="1"/>
|
||||
</Value>
|
||||
<Value genre="config" index="32" label="Low battery threshold" max="50" min="10" size="1" type="list" units="%" value="20">
|
||||
<Help>This parameter defines a battery level as the “low battery”.</Help>
|
||||
<Item label="10" value="10"/>
|
||||
<Item label="20" value="20"/>
|
||||
<Item label="30" value="30"/>
|
||||
<Item label="40" value="40"/>
|
||||
<Item label="50" value="50"/>
|
||||
</Value>
|
||||
</CommandClass>
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="2">
|
||||
<Group index="1" label="Lifeline" max_associations="5"/>
|
||||
<Group index="2" label="Basic Set" max_associations="5"/>
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
BIN
config/images/homeseer/hs-ds100plus.png
Normal file
BIN
config/images/homeseer/hs-ds100plus.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 157 KiB |
|
@ -1,5 +1,5 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<ManufacturerSpecificData Revision="41" xmlns="https://github.com/OpenZWave/open-zwave">
|
||||
<ManufacturerSpecificData Revision="42" xmlns="https://github.com/OpenZWave/open-zwave">
|
||||
<Manufacturer id="0028" name="2B Electronics"></Manufacturer>
|
||||
<Manufacturer id="0098" name="2GIG Technologies">
|
||||
<Product config="2gig/ct50e.xml" id="015e" name="CT50e Thermostat" type="3200"/>
|
||||
|
@ -876,6 +876,7 @@
|
|||
<Product config="homeseer/hs-wd100plus.xml" id="3034" name="HS-WD100+ Wall Dimmer" type="4447"/>
|
||||
<Product config="homeseer/hs-ws200plus.xml" id="3035" name="HS-WS200+ Wall Switch" type="4447"/>
|
||||
<Product config="homeseer/hs-wd200plus.xml" id="3036" name="HS-WD200+ Wall Dimmer" type="4447"/>
|
||||
<Product type="201" id="8" name="HS-DS100+ Door/Window Sensor" config="homeseer/hs-ds100plus.xml"/>
|
||||
<Product config="homeseer/hs-ms100plus.xml" id="9" name="HS-MS100+ Motion Sensor" type="201"/>
|
||||
<Product config="homeseer/hs-ls100plus.xml" id="a" name="HS-LS100+ Leak Sensor" type="201"/>
|
||||
<Product config="homeseer/hs-fls100plus.xml" id="000b" name="HS-FLS100+ Floodlight Sensor" type="0201"/>
|
||||
|
|
|
@ -1295,6 +1295,10 @@
|
|||
'Revision' => '3',
|
||||
'md5' => '8d4ea274a67cfc24dd3c20205bd4e2fc8133233ed99fbb2596d7162298c0ad4ed07ab327356fb5a07e1424d6634de27227bc03b70c7a9f06754f82360d854537'
|
||||
},
|
||||
'config/homeseer/hs-ds100plus.xml' => {
|
||||
'Revision' => '1',
|
||||
'md5' => 'bf724e9e2f52776c8837b1a46d465d2b20bdab25733b1775d8665e00329c82f1b9a194a5e6c2539df754abc90e3c83b6044388e1e7019b2820f9ea3c63e64aeb'
|
||||
},
|
||||
'config/homeseer/hs-fc200plus.xml' => {
|
||||
'Revision' => '3',
|
||||
'md5' => '2c8076f31efdef00d014a58a4acc35db4e256175c57e2e93c3db183c66f52fe7a47feea880c2cd8723883fa860a540b81bb52cfd17c04072b7b9a5a6e06126c8'
|
||||
|
|
|
@ -339,6 +339,7 @@ DISTFILES = .gitignore \
|
|||
config/heltun/he-zw-therm-fc1.xml \
|
||||
config/heltun/he-zw-therm-fl2.xml \
|
||||
config/homeseer/ezmotionplus.xml \
|
||||
config/homeseer/hs-ds100plus.xml \
|
||||
config/homeseer/hs-fc200plus.xml \
|
||||
config/homeseer/hs-fls100plus.xml \
|
||||
config/homeseer/hs-fs100plus.xml \
|
||||
|
@ -614,6 +615,7 @@ DISTFILES = .gitignore \
|
|||
config/images/heiman/HS1SA-Z.png \
|
||||
config/images/heiman/HS1WL-Z.png \
|
||||
config/images/heiman/HS2SK-Z.png \
|
||||
config/images/homeseer/hs-ds100plus.png \
|
||||
config/images/homeseer/hs-fc200plus.png \
|
||||
config/images/homeseer/hs-fls100plus.png \
|
||||
config/images/homeseer/hs-ls100plus.png \
|
||||
|
|
Loading…
Add table
Reference in a new issue