Fix config parameter 68 in ZMNHDDX.xml #1995 (#2001)

This commit is contained in:
Peter Gebruers 2019-11-17 16:07:35 +01:00 committed by GitHub
parent c1d5089796
commit cbe2b60f94
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23
2 changed files with 5 additions and 4 deletions

View file

@ -1,4 +1,4 @@
<Product Revision="8" xmlns="https://github.com/OpenZWave/open-zwave">
<Product Revision="9" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0159:0051:0001</MetaDataItem>
<MetaDataItem name="ProductPic">images/qubino/ZMNHDDx.png</MetaDataItem>
@ -35,6 +35,7 @@ Please use reset procedure only when the network primary controller is missing o
<Entry author="Justin Hammond - Justin@dynam.ac" date="02 Jun 2019" revision="6">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2077/xml</Entry>
<Entry author="Justin Hammond - Justin@dynam.ac" date="02 Jun 2019" revision="7">Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2114/xml</Entry>
<Entry author="Chris Nesbitt-Smith - chris@cns.me.uk" date="27 Sep 2019" revision="8">Tweak config label for consistency of both buttons</Entry>
<Entry author="Peter Gebruers - peter.gebruers@gmail.com on behalf of jtonk" date="17 Nov 2019" revision="9">fixes: qubino wrong config parameter 68 in ZMNHDDX.xml #1995</Entry>
</ChangeLog>
</MetaData>
<!--
@ -148,7 +149,7 @@ http://qubino.com/download/990/
<Item label="respect start level" value="0"/>
<Item label="ignore start level" value="1"/>
</Value>
<Value genre="config" index="68" instance="1" label="Dimming duration" max="1" min="0" size="1" type="list" value="0">
<Value genre="config" index="68" instance="1" label="Dimming duration" max="127" min="0" size="1" type="byte" value="0">
<Help>This parameter is used with association group 3.
The Duration field MUST specify the time that the transition should take from the current value to the new target value.
A supporting device SHOULD respect the specified Duration value.

View file

@ -1984,8 +1984,8 @@
'md5' => '7883b97dc7151ac7c550f56adbafb086a548613a14617da51232bb1e199a97144f89205622555efdac851e2fde437e2e00e65066c591ac1f1d622e7b57a1c59b'
},
'config/qubino/ZMNHDDx.xml' => {
'Revision' => 8,
'md5' => '6436d7a0c6eeeed1221a4bc4685ff908cbf519f51d96bc755e59b98a379665ac4a80ab3003f146400dc8b34cc9350168d7f6da2697c1d54432ec40c7771cef2a'
'Revision' => 9,
'md5' => 'de18029a1539e10dd15fc85ede084182e1cfcbc78325602ca6e5b428884f6db6ce1bebdbea331a8ca0f4ba133828c09f13ce6c1f8486871a5ca9c17258358ba1'
},
'config/qubino/ZMNHHDx.xml' => {
'Revision' => '1',