Update config for MIMO2+

This commit is contained in:
Justin Hammond 2019-05-24 14:09:51 +08:00
parent d4a0b8b52e
commit d358d160a4
2 changed files with 86 additions and 60 deletions

View file

@ -1,60 +1,86 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="1">
<!--
https://products.z-wavealliance.org/products/1893
https://static1.squarespace.com/static/57363221555986b60e62f0f0/t/5919d919ff7c50802f0b93da/1494866202716/Tech+Appendix+MIMO2%2B+8May2017+removed+MI+address.pdf
-->
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="byte" index="1" genre="config" label="Relay 1 Configuration" units="" min="0" max="255" value="5">
<Help>
0 The relay will remain latched in the position it is commanded to (open/off or closed/on).
-128 to 127 Set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. For example, a value of 2 = 0.2 Seconds.
</Help>
</Value>
<Value type="byte" index="2" genre="config" label="Relay 2 Configuration" units="" min="0" max="255" value="5">
<Help>
0 The relay will remain latched in the position it is commanded to (open/off or closed/on).
-128 to 127 Set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. For example, a value of 2 = 0.2 Seconds.
</Help>
</Value>
<Value type="byte" index="3" genre="config" label="SIG 1 Multilevel Trigger Settings" units="" min="0" max="255" value="167">
<Help>Set this value to trigger between thresholds.</Help>
</Value>
<Value type="byte" index="4" genre="config" label="SIG 1 Lower Threshold, High" min="0" max="255" value="144">
<Help>Set this value to set the lower threshold high number</Help>
</Value>
<Value type="byte" index="5" genre="config" label="SIG 1 Lower Threshold, Low" min="0" max="255" value="128">
<Help>Set this to set the lower threshold low number.</Help>
</Value>
<Value type="byte" index="6" genre="config" label="SIG 1 Upper Threshold, High" min="0" max="255" value="255">
<Help>Set this to set the upper threshold, high number</Help>
</Value>
<Value type="byte" index="7" genre="config" label="SIG 1 Upper Threshold, Low" min="0" max="255" value="254">
<Help>Set this to set the upper threshold low number</Help>
</Value>
<Value type="byte" index="9" genre="config" label="SIG 2 Multilevel Trigger Settings" units="" min="0" max="255" value="167">
<Help>Set this value to trigger between thresholds.</Help>
</Value>
<Value type="byte" index="10" genre="config" label="SIG 2 Lower Threshold, High" min="0" max="255" value="144">
<Help>Set this value to set the lower threshold high number</Help>
</Value>
<Value type="byte" index="11" genre="config" label="SIG 2 Lower Threshold, Low" min="0" max="255" value="128">
<Help>Set this to set the lower threshold low number.</Help>
</Value>
<Value type="byte" index="12" genre="config" label="SIG 2 Upper Threshold, High" min="0" max="255" value="255">
<Help>Set this to set the upper threshold, high number</Help>
</Value>
<Value type="byte" index="13" genre="config" label="SIG 2 Upper Threshold, Low" min="0" max="255" value="254">
<Help>Set this to set the upper threshold low number</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="3">
<Group index="1" max_associations="2" label="Lifeline"/>
<Group index="2" max_associations="2" label="SIG1"/>
<Group index="3" max_associations="2" label="SIG2"/>
</Associations>
</CommandClass>
</Product>
<Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0084:0204:0463</MetaDataItem>
<MetaDataItem name="ProductPic">images/fortrezz/mimo2plus.png</MetaDataItem>
<MetaDataItem id="0204" name="ZWProductPage" type="0463">https://products.z-wavealliance.org/products/1893/</MetaDataItem>
<MetaDataItem name="ResetDescription">Device Reset to Factory Defaults Press and hold the program button for 15 seconds and then release. This can be done while the device is either in or out of a network. CAUTION When this is done in-network, the device will no longer be in the network and all configurations and associations will be set to default.
Please use this procedure only when your network primary controller is missing or otherwise inoperable.</MetaDataItem>
<MetaDataItem name="Description">The MIMO2+ module provides two voltage inputs and two relay outputs (either can be wired normally open or normally closed).
Z-Wave™ messages can be used to read the inputs and control the outputs. The inputs are very configurable for different trigger conditions and can even be mapped to control the outputs. The module includes a button for Z-Wave™ inclusion/exclusion and an LED for various status indications. The functionality of the SIG1 and SIG2 inputs is:
- Analog Triggering: Various trigger conditions can be set for high-to-low and low-to-high transitions. This provides great flexibility for capturing digital or analog events in a wide variety of applications. The trigger status can be automatically sent to the controller.
- Associations: Each input can be associated with up to two other Z-Wave™ devices, so that, for example, an associated device will automatically turn on (or off) based on the occurrence of a trigger event.
Voltage Reporting: The analog input voltage levels can also be sent to the controller.
The physical outputs are relays that are typically activated by Z-Wave™ commands. However, the user can override Z-Wave™ control by configuring the input trigger conditions to be mapped to the output relays via logical AND/OR functions.
</MetaDataItem>
<MetaDataItem name="Name">MIMO2+</MetaDataItem>
<MetaDataItem id="0204" name="FrequencyName" type="0463">U.S. / Canada / Mexico</MetaDataItem>
<MetaDataItem name="ExclusionDescription">1) Activate exclusion mode on your Z-wave controller.
2) Press the program button once.
3) LED will blink 4 times quickly to indicate "in network" status.</MetaDataItem>
<MetaDataItem name="InclusionDescription">1) Activate inclusion mode on your Z-wave controller.
2) Press the program button once.
3) LED will blink 2 times quickly to indicate "in network" status.</MetaDataItem>
<MetaDataItem id="0204" name="Identifier" type="0463">MIMO2+</MetaDataItem>
<MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&amp;filename=Manuals/1893/MIMO2 Plus Manual and Tech Appendix 2016-07-29.pdf</MetaDataItem>
<ChangeLog>
<Entry author="Justin Hammond - Justin@dynam.ac" date="24 May 2019" revision="2">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1893/xml</Entry>
</ChangeLog>
</MetaData>
<!--
https://products.z-wavealliance.org/products/1893
https://static1.squarespace.com/static/57363221555986b60e62f0f0/t/5919d919ff7c50802f0b93da/1494866202716/Tech+Appendix+MIMO2%2B+8May2017+removed+MI+address.pdf
-->
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value genre="config" index="1" label="Relay 1 Configuration" max="255" min="0" type="byte" units="" value="5">
<Help>
0 The relay will remain latched in the position it is commanded to (open/off or closed/on).
-128 to 127 Set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. For example, a value of 2 = 0.2 Seconds.
</Help>
</Value>
<Value genre="config" index="2" label="Relay 2 Configuration" max="255" min="0" type="byte" units="" value="5">
<Help>
0 The relay will remain latched in the position it is commanded to (open/off or closed/on).
-128 to 127 Set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. For example, a value of 2 = 0.2 Seconds.
</Help>
</Value>
<Value genre="config" index="3" label="SIG 1 Multilevel Trigger Settings" max="255" min="0" type="byte" units="" value="167">
<Help>Set this value to trigger between thresholds.</Help>
</Value>
<Value genre="config" index="4" label="SIG 1 Lower Threshold, High" max="255" min="0" type="byte" value="144">
<Help>Set this value to set the lower threshold high number</Help>
</Value>
<Value genre="config" index="5" label="SIG 1 Lower Threshold, Low" max="255" min="0" type="byte" value="128">
<Help>Set this to set the lower threshold low number.</Help>
</Value>
<Value genre="config" index="6" label="SIG 1 Upper Threshold, High" max="255" min="0" type="byte" value="255">
<Help>Set this to set the upper threshold, high number</Help>
</Value>
<Value genre="config" index="7" label="SIG 1 Upper Threshold, Low" max="255" min="0" type="byte" value="254">
<Help>Set this to set the upper threshold low number</Help>
</Value>
<Value genre="config" index="9" label="SIG 2 Multilevel Trigger Settings" max="255" min="0" type="byte" units="" value="167">
<Help>Set this value to trigger between thresholds.</Help>
</Value>
<Value genre="config" index="10" label="SIG 2 Lower Threshold, High" max="255" min="0" type="byte" value="144">
<Help>Set this value to set the lower threshold high number</Help>
</Value>
<Value genre="config" index="11" label="SIG 2 Lower Threshold, Low" max="255" min="0" type="byte" value="128">
<Help>Set this to set the lower threshold low number.</Help>
</Value>
<Value genre="config" index="12" label="SIG 2 Upper Threshold, High" max="255" min="0" type="byte" value="255">
<Help>Set this to set the upper threshold, high number</Help>
</Value>
<Value genre="config" index="13" label="SIG 2 Upper Threshold, Low" max="255" min="0" type="byte" value="254">
<Help>Set this to set the upper threshold low number</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="3">
<Group index="1" label="Lifeline" max_associations="2"/>
<Group index="2" label="SIG1" max_associations="2"/>
<Group index="3" label="SIG2" max_associations="2"/>
</Associations>
</CommandClass>
</Product>