http://www.openzwave.com/device-database/001A:0000:4441
images/cooper/RF9542-Z.png
https://products.z-wavealliance.org/products/971/
U.S. / Canada / Mexico
RF9542-Z
Aspire RF™ Accessory Dimmers replace regular switches or dimmers to provide local and remote ON/OFF/DIM/BRIGHT control. The device also provides multi-location control or virtual 3-way remote ON/OFF/DIM/BRIGHT control without the need for traditional 3-way wiring or a dedicated traveler wire. Aspire RF Accessory Dimmers provide other programmable functions (scenes, events, association, child lockout, etc.) when used with Aspire RF or other Z-Wave® compliant controller*. Each dimmer can be manually controlled and remotely controlled by commands sent from an Aspire RF controller (RFHDCSG, RFTDCSG, RFBER) or other Z-Wave compatible controllers or programs. Aspire RF Dimmers utilize existing 120V/AC 60Hz standard house wiring and fit in standard wallboxes. No new wiring is needed.
Dimmer Accessory Switch
Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/745/xml
Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/971/xml
http://www.cooperindustries.com/content/public/en/wiring_devices/products/lighting_controls/aspire_rf_wireless/dimmers/aspire_rf_accessory_w_leds_rf9542_z_.html
The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex)
Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation
Power up state of the device
Enables this switch to participate in panic mode
The amount of time in seconds the switch will take to reach the desired dim level. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex)