<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Yale Touchscreen Deadbolt (YRD220)
http://ozw.my-ho.st/Yale/Yale%20ZWave%20Developer%20Guide.pdf
http://products.z-wavealliance.org/products/1972/configs
http://products.z-wavealliance.org/products/1973/configs
-->
<!-- Configuration -->
<CommandClass id="112">
<Value type="list" size="1" genre="config" instance="1" index="1" label="Audio Mode" value="3">
<Help>Disable the door sensor alarm function.</Help>
<Item label="Silent" value="1" />
<Item label="Low" value="2" />
<Item label="High" value="3" />
</Value>
<Value type="list" size="1" genre="config" instance="1" index="2" label="Auto Relock" value="0">
<Help></Help>
<Item label="Off" value="0" />
<Item label="On" value="255" />
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Re-lock Time" size="1" min="5" max="255" units="seconds" value="30">
<Help>seconds; after successful code entry and unit unlocks, it will automatically re-lock after specified time (30 = default value)</Help>
</Value>
<Value type="list" size="1" genre="config" instance="1" index="4" label="Wrong Code Entry Limit" min="1" max="7" value="5">
<Help>
The number of invalid code entries lock will accept before sending TAMPER Alarm.
When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default)
</Help>
<Item label="1" value="1" />
<Item label="2" value="2" />
<Item label="3" value="3" />
<Item label="4" value="4" />
<Item label="5" value="5" />
<Item label="6" value="6" />
<Item label="7" value="7" />
</Value>
<Value type="list" size="1" genre="config" instance="1" index="5" label="Language" min="1" max="3" value="1">
<Help>
The number of invalid code entries lock will accept before sending TAMPER Alarm.
When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default)
</Help>
<Item label="English" value="1" />
<Item label="Spanish" value="2" />
<Item label="French" value="3" />
</Value>
<Value type="byte" genre="config" instance="1" index="7" label="Shutdown Time" size="1" min="5" max="255" units="seconds" value="30">
<Help>number of seconds unit will be inoperable after number of wrong code entries is exceeded (30 = default)</Help>
</Value>
<Value type="list" size="1" genre="config" instance="1" index="8" label="Operating Mode" min="0" max="2" value="1">
<Help>
The number of invalid code entries lock will accept before sending TAMPER Alarm.
When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter. (5 = default)
</Help>
<Item label="Normal" value="0" />
<Item label="Vacation" value="1" />
<Item label="Privacy" value="2" />
</Value>
<Value type="list" size="1" genre="config" instance="1" index="11" label="One Touch Locking" value="0">
<Help></Help>
<Item label="Off" value="0"/>
<Item label="On" value="255"/>
</Value>
<Value type="list" size="1" genre="config" instance="1" index="12" label="Privacy Button" value="0">
<Help></Help>
<Item label="Off" value="0"/>
<Item label="On" value="255"/>
</Value>
<Value type="list" size="1" genre="config" instance="1" index="13" label="Lock Status LED" value="0">
<Help></Help>
<Item label="Off" value="0"/>
<Item label="On" value="255"/>
</Value>
<Value type="list" size="1" genre="config" instance="1" index="15" label="Reset to Factory Defaults" value="0">
<Help></Help>
<Item label="Off" value="0"/>
<Item label="On" value="255"/>
</Value>
</CommandClass>
<CommandClass id="113">
<!-- These Door Locks don't send a DoorLockReport when the
Lock Status is Changed, but instead send a Alarm Message -
So we trigger a Refresh of the DoorLock Command Class when
we recieve a Alarm Message Instead -->
<TriggerRefreshValue Genre="user" Index="0" Instance="1">
<RefreshClassValue CommandClass="98" RequestFlags="0" Index="1" Instance="1" />
</TriggerRefreshValue>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Lifeline"/>
</Associations>
</CommandClass>
</Product>