<Product Revision="7" xmlns="https://github.com/OpenZWave/open-zwave">
|
|
<!-- COMMAND_CLASS_SWITCH_MULTILEVEL. This class is in the list reported by the device, but it does not respond to requests -->
|
|
<CommandClass id="38">
|
|
<Compatibility>
|
|
<GetSupported>false</GetSupported>
|
|
</Compatibility>
|
|
</CommandClass>
|
|
<!-- Configuration -->
|
|
<CommandClass id="112">
|
|
<Value genre="config" index="9" instance="1" label="Saving state before power failure" max="1" min="0" size="1" type="list" value="1">
|
|
<Help>Saving state before power failure</Help>
|
|
<Item label="State NOT saved at power failure, all outputs are set to OFF upon power restore" value="0"/>
|
|
<Item label="State saved at power failure, all outputs are set to previous state upon power restore" value="1"/>
|
|
</Value>
|
|
<Value genre="config" index="10" instance="1" label="First channel - operating mode" max="5" min="0" size="1" type="list" value="0">
|
|
<Help>This parameter allows to choose operating for the 1st channel controlled by the S1 switch.</Help>
|
|
<Item label="Standard operation" value="0"/>
|
|
<Item label="Delay On" value="1"/>
|
|
<Item label="Delay Off" value="2"/>
|
|
<Item label="Auto On" value="3"/>
|
|
<Item label="Auto Off" value="4"/>
|
|
<Item label="Flashing Mode" value="5"/>
|
|
</Value>
|
|
<Value genre="config" index="11" instance="1" label="First channel - reaction to switch for delay/auto ON/OFF modes" max="2" min="0" size="1" type="list" value="0">
|
|
<Help>This parameter determines how the device in timed mode reacts to pushing the switch connected to the S1 terminal.</Help>
|
|
<Item label="Cancel mode and set target state" value="0"/>
|
|
<Item label="No reaction to switch - mode runs until it ends" value="1"/>
|
|
<Item label="Reset timer - start counting from the beginning" value="2"/>
|
|
</Value>
|
|
<Value genre="config" index="12" instance="1" label="First channel - time parameter for delay/auto ON/OFF modes" max="32000" min="1" size="2" type="short" value="50">
|
|
<Help>This parameter allows to set time parameter used in timed modes. (s)</Help>
|
|
</Value>
|
|
<Value genre="config" index="13" instance="1" label="First channel - pulse time for flashing mode" max="32000" min="1" size="2" type="short" value="5">
|
|
<Help>
|
|
This parameter allows to set time of switching to opposite state in flashing mode.
|
|
1-32000 (0.1-3200.0s, 0.1s step)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="15" instance="1" label="Second channel - operating mode" max="5" min="0" size="1" type="list" value="0">
|
|
<Help>This parameter allows to choose operating for the 2st channel controlled by the S2 switch.</Help>
|
|
<Item label="Standard operation" value="0"/>
|
|
<Item label="Delay On" value="1"/>
|
|
<Item label="Delay Off" value="2"/>
|
|
<Item label="Auto On" value="3"/>
|
|
<Item label="Auto Off" value="4"/>
|
|
<Item label="Flashing Mode" value="5"/>
|
|
</Value>
|
|
<Value genre="config" index="16" instance="1" label="Second channel - reaction to switch for delay/auto ON/OFF modes" max="2" min="0" size="1" type="list" value="0">
|
|
<Help>This parameter determines how the device in timed mode reacts to pushing the switch connected to the S2 terminal.</Help>
|
|
<Item label="Cancel mode and set target state" value="0"/>
|
|
<Item label="No reaction to switch - mode runs until it ends" value="1"/>
|
|
<Item label="Reset timer - start counting from the beginning" value="2"/>
|
|
</Value>
|
|
<Value genre="config" index="17" instance="1" label="Second channel - time parameter for delay/auto ON/OFF modes" max="32000" min="1" size="2" type="short" value="50">
|
|
<Help>This parameter allows to set time parameter used in timed modes. (s)</Help>
|
|
</Value>
|
|
<Value genre="config" index="18" instance="1" label="Second channel - pulse time for flashing mode" max="32000" min="1" size="2" type="short" value="5">
|
|
<Help>
|
|
This parameter allows to set time of switching to opposite state in flashing mode.
|
|
1-32000 (0.1-3200.0s, 0.1s step)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="20" instance="1" label="Switch type" max="2" min="0" size="1" type="list" value="2">
|
|
<Help>Inputs type configuration</Help>
|
|
<Item label="Momentary switch" value="0"/>
|
|
<Item label="Toggle switch (contact closed - On, contact opened - OFF)" value="1"/>
|
|
<Item label="Toggle switch (device changes status when switch changes status)" value="2"/>
|
|
</Value>
|
|
<Value genre="config" index="21" instance="1" label="Flashing mode report" max="1" min="0" size="1" type="list" value="0">
|
|
<Help>Enabled / Disabled reports on Flashing mode</Help>
|
|
<Item label="Disabled" value="0"/>
|
|
<Item label="Enabled" value="1"/>
|
|
</Value>
|
|
<Value genre="config" index="27" instance="1" label="Associations in Z-Wave network security mode" max="15" min="0" size="1" type="byte" value="15">
|
|
<Help>
|
|
This parameter defines how commands are sent to specified association groups: as secure or non-secure.
|
|
Parameter is active only in Z-Wave network security mode.
|
|
This parameter does not apply to 1st lifeline group.
|
|
1 - 2nd group sent as secure.
|
|
2 - 3rd group sent as secure.
|
|
4 - 4th group sent as secure.
|
|
8 - 5th group sent as secure.
|
|
Default setting: 15 (all)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="28" instance="1" label="S1 switch - scenes sent" max="15" min="0" size="1" type="byte" value="0">
|
|
<Help>
|
|
This parameter determines which actions result in sending scene IDs assigned to them.
|
|
1 - Key pressed 1 time.
|
|
2 - Key pressed 2 times.
|
|
4 - Key pressed 3 times.
|
|
8 - Key Hold Down and Key Released.
|
|
Default setting: 0 (none)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="29" instance="1" label="S2 switch - scenes sent" max="15" min="0" size="1" type="byte" value="0">
|
|
<Help>
|
|
This parameter determines which actions result in sending scene IDs assigned to them.
|
|
1 - Key pressed 1 time.
|
|
2 - Key pressed 2 times.
|
|
4 - Key pressed 3 times.
|
|
8 - Key Hold Down and Key Released.
|
|
Default setting: 0 (none)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="30" instance="1" label="S1 associations sent to 2nd and 3rd association groups" max="15" min="0" size="1" type="byte" value="0">
|
|
<Help>
|
|
This parameter determines which actions are ignored when sending commands to devices associated in 2nd and 3rd association group.
|
|
All actions are active by default.
|
|
1 - ignore turning On with 1 click of the switch.
|
|
2 - ignore turning OFF with 1 click of the switch.
|
|
4 - ignore holding and releasing the switch.
|
|
8 - ignore double click of the switch.
|
|
Default setting: 0
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="31" instance="1" label="S1 Switch ON value sent to 2nd and 3rd association groups" max="255" min="0" size="2" type="short" value="255">
|
|
<Help>
|
|
This parameter determines value sent with Switch On command to devices associated in 2nd and 3rd association group.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="32" instance="1" label="S1 Switch OFF value sent to 2nd and 3rd association groups" max="255" min="0" size="2" type="short" value="0">
|
|
<Help>
|
|
This parameter determines value sent with Switch Off command to devices associated in 2nd and 3rd association group.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="33" instance="1" label="S1 Switch Double Click value sent to 2nd and 3rd association groups" max="255" min="0" size="2" type="short" value="99">
|
|
<Help>
|
|
This parameter determines value sent with Double Click command to devices associated in 2nd and 3rd association group.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="35" instance="1" label="S2 associations sent to 4th and 5th association groups" max="15" min="0" size="1" type="byte" value="0">
|
|
<Help>
|
|
This parameter determines which actions are ignored when sending commands to devices associated in 4th and 5th association group.
|
|
All actions are active by default.
|
|
1 - ignore turning On with 1 click of the switch.
|
|
2 - ignore turning OFF with 1 click of the switch.
|
|
4 - ignore holding and releasing the switch.
|
|
8 - ignore double click of the switch.
|
|
Default setting: 0
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="36" instance="1" label="S2 Switch ON value sent to 4th and 5th association groups" max="255" min="0" size="2" type="short" value="255">
|
|
<Help>
|
|
This parameter determines value sent with Switch On command to devices associated in 4th and 5th association group.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="37" instance="1" label="S2 Switch OFF value sent to 4th and 5th association groups" max="255" min="0" size="2" type="short" value="0">
|
|
<Help>
|
|
This parameter determines value sent with Switch Off command to devices associated in 4th and 5th association group.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="38" instance="1" label="S2 Switch Double Click value sent to 4th and 5th association groups" max="255" min="0" size="2" type="short" value="99">
|
|
<Help>
|
|
This parameter determines value sent with Double Click command to devices associated in 4th and 5th association group.
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="40" instance="1" label="Reaction to General Alarm" max="3" min="0" size="1" type="list" value="3">
|
|
<Help>This parameter determines how the device will react to General Alarm frame.</Help>
|
|
<Item label="Ignored" value="0"/>
|
|
<Item label="Turn On" value="1"/>
|
|
<Item label="Turn OFF" value="2"/>
|
|
<Item label="Flash" value="3"/>
|
|
</Value>
|
|
<Value genre="config" index="41" instance="1" label="Reaction to Flood Alarm" max="3" min="0" size="1" type="list" value="2">
|
|
<Help>This parameter determines how the device will react to Flood Alarm frame.</Help>
|
|
<Item label="Ignored" value="0"/>
|
|
<Item label="Turn On" value="1"/>
|
|
<Item label="Turn OFF" value="2"/>
|
|
<Item label="Flash" value="3"/>
|
|
</Value>
|
|
<Value genre="config" index="42" instance="1" label="Reaction to CO/CO2/Smoke Alarm" max="3" min="0" size="1" type="list" value="3">
|
|
<Help>This parameter determines how the device will react to CO/CO2/Smoke Alarm frame.</Help>
|
|
<Item label="Ignored" value="0"/>
|
|
<Item label="Turn On" value="1"/>
|
|
<Item label="Turn OFF" value="2"/>
|
|
<Item label="Flash" value="3"/>
|
|
</Value>
|
|
<Value genre="config" index="43" instance="1" label="Reaction to Heat Alarm" max="3" min="0" size="1" type="list" value="1">
|
|
<Help>This parameter determines how the device will react to Heat alarm frame.</Help>
|
|
<Item label="Ignored" value="0"/>
|
|
<Item label="Turn On" value="1"/>
|
|
<Item label="Turn OFF" value="2"/>
|
|
<Item label="Flash" value="3"/>
|
|
</Value>
|
|
<Value genre="config" index="44" instance="1" label="Flashing alarm duration" max="32000" min="1" size="2" type="short" value="600">
|
|
<Help>
|
|
This parameter allows to set duration of flashing alarm mode.
|
|
1-32000 (0.1-32000s, 1s step) Default: 600 (10min)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="50" instance="1" label="First channel - power reports" max="100" min="1" size="2" type="short" value="20">
|
|
<Help>
|
|
This parameter determines the minimum change in consumed power
|
|
that will result in sending new power report to the main controller.
|
|
1-100 (%) Default 20 (20%)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="51" instance="1" label="First channel - minimal time between power reports" max="120" min="1" size="2" type="short" value="10">
|
|
<Help>
|
|
This parameter determines minimum time that has to elapse before
|
|
sending new power report to the main controller.
|
|
1-120 (s) Default 10 (10s)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="53" instance="1" label="First channel - energy reports" max="32000" min="1" size="2" type="short" value="100">
|
|
<Help>
|
|
This parameter determines the minimum change in consumed energy
|
|
that will result in sending new energy report to the main controller.
|
|
1-32000 (0.01-320 kWh) Default 100 (1kWh)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="58" instance="1" label="Periodic power reports" max="32000" min="1" size="2" type="short" value="3600">
|
|
<Help>
|
|
This parameter determines in what time interval the periodic
|
|
power reports are sent to the main controller.
|
|
1-32000 (s) Default 3600 (1h)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="59" instance="1" label="Periodic energy reports" max="32000" min="1" size="2" type="short" value="3600">
|
|
<Help>
|
|
This parameter determines in what time interval the periodic
|
|
power reports are sent to the main controller.
|
|
1-32000 (s) Default 3600 (1h)
|
|
</Help>
|
|
</Value>
|
|
<Value genre="config" index="60" instance="1" label="Measuring energy consumed by the device itself" max="1" min="0" size="1" type="list" value="0">
|
|
<Help>
|
|
This parameter determines whether energy metering should include
|
|
the amount of energy consumed by the device itself. Results are
|
|
being added to energy reports for first endpoint.
|
|
</Help>
|
|
<Item label="function inactive" value="0"/>
|
|
<Item label="function active" value="1"/>
|
|
</Value>
|
|
</CommandClass>
|
|
<!-- -->
|
|
<CommandClass id="96">
|
|
<Compatibility>
|
|
<MapRootToEndpoint>true</MapRootToEndpoint>
|
|
</Compatibility>
|
|
</CommandClass>
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="5">
|
|
<Group index="1" label="Lifeline" max_associations="1"/>
|
|
<Group index="2" label="On/Off S1" max_associations="5"/>
|
|
<Group index="3" label="Dimmer S1" max_associations="5"/>
|
|
<Group index="4" label="On/Off S2" max_associations="5"/>
|
|
<Group index="5" label="Dimmer S2" max_associations="5"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
<CommandClass id="142">
|
|
<Compatibility>
|
|
<ForceInstances>true</ForceInstances>
|
|
</Compatibility>
|
|
</CommandClass>
|
|
</Product>
|